Customization: | Available |
---|---|
Type: | Heat Alarm |
Signal Transmission: | Wireless Alarm |
Still deciding? Get samples of US$ 10.4/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Module Number | THS898-HI |
Power Supply | AC 220-240V with DC 9V back up |
Heat Sensitivity | 54ºC to 65 ºC |
Operation Current | ≤ 100mA with AC power |
Comply with Standard | BS 5446-2:2003 |
Alarm Volume | >85dB(A) @ 3 meters |
Hush Time | 8 mins |
Product Life Time | >10 years |
Wired interconnection | Up to 40pcs |
Humidity Range | <93% relative humidity (RH) |
Temperature Range | 0ºC to 65ºC |
Plastic Material | V0 level flame retardant ABS |
Product Size | 140mm in diameter x 58.8mm depth |
Standby mode | After the product is installed, if the heat alarm device is operating properly, the red LED Flashes once every 40 seconds. |
Local Alarm mode | When the heat alarm device detect the environmental temperature between 54 - 65ºC, the red LED will flash once per second with pulsating alarm until the hot air is removed. |
Interconnection alarm mod | When the heat alarm device detect the environmental temperature between 54 - 65ºC, the alarm will send local alarm signal, other interconnection alarms will send alarm signals. The wired interconnection alarms will go into interconnection alarm mode: BI - BI - pause 1.2s, with the red LED flashes, this alarm pattern is repeated. |
Low battery mode | when the battery voltage is low than threshold, the red LED will flash once every 40 seconds with a sound of "chrip". |
Fault mode | If the alarm detection signal decays below threshold, the alarm chirp occurs without LED flashes every 32 seconds. |
Silence mode | Press the test button at least 2 seconds, it will go into silence mode for approx 8 minutes. That will desensitize the alarm sensitivity temporarily. At this time, the red LED will flash once every 8 seconds. |
No disturb mode | When the alarm device is in low battery mode,in order to avoid disturbing you at night, please press the test button for 3 seconds which will mute this warning tone for about 14 hours. After 14 hours, the warning tone will still go off. The red LED will flash once every 40 seconds during No disturb mode. |
Test mode | Test the unit to ensure proper operation by pressing the test button. At this time, the red LED will flash once per second with pulsating alarm until test button is released. |